NAPCO Gemini Hybrid control panel 8 to 255 zone max


(SKU# : GEM-X255)


Gemini X255 is the expansive hardwire/wireless control offering 255 fully-programmable zones, 195 users, fuseless operation & supports the full line of top performing Gemini Wireless.


DESCRIPTIONS

NAPCO’s Gemini GEM-X255 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel of modular design. Integrally an 8-zone panel, it will support up to 255 zones with optional zone expansion modules, wireless receiver modules and/or GEM-RP1CAe2 Keypads. Each panel includes an integral digital communicator. The control panel features programmable area partitioning. That is, the system may be divided into up to 8 discrete multiple-zone areas, each allowing access by only those users programmed for their respective area.

FEATURES

  • 8 to 255 zones, hardwire or wireless zonesfrom GEM EZM8 zone- expansion modules andRP1/K1 4-zone keypads or wireless points usingGemini receivers
  • Including up to 8 2-wire fire zones
  • Up to 195 individually coded users, each with aprogrammable authority level
  • Exclusive RS232 panel-port supports PC homeautomation/ networking integration for 9600baud comprehensive communications
  • Fuseless maintenance-free operation
  • 8 End-of-line-resistor burglary zones programmablefor area, exit/entry delay, interior, follower, dayzone, chime, fire option, sensor watch, swingershutdown, zone anding and a variety of otherfeatures
  • 3 on-board relay outputs; expandable to 99
  • Three keypad panics: fire, police & auxiliary
  • Up to 8 independent area partitions
  • Up to 8 separate access stations for up to 195users
  • Up to 64 separately-addressable X-10 devices withthe GEM-X10KIT
  • English-language prompts & system status messagesfrom keypad (GEM-RP1CAe2 installed “with255 support” only)
  • User-customized zone descriptions, reprogrammableas required
  • Supports 2-wire and 4-wire smoke detectors
  • Reports alarms, restores and troubles by zone
  • 255 event schedule
  • 800 event log
  • Overview mode permits monitoring and control oftotal system from one keypad
  • Supports up to 4 RF receivers
  • Guard-tour programmable for start time, tourlength, and check points (tour stations)
  • 2 programmable entry delay times
  • 2 interior-bypass groups
  • Dynamic battery test interrupts charging and placesbattery under load every four hours
  • Chime by zone; programmable duration
  • Non-volatile RAM retains memory during powerlosses
  • PCD-Windows programmable
  • Auto-download log
  • Exclusive V.A.L.I.D.™ FEATURE (VerifyingAutomatic Line Integrity Diagnostic) reduces falsealarms due to changes in line resistance

Communicator features

  • Compatible with all major receiver formats,including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2Express and Point ID
  • Rotary dial and TouchTone™ with rotary backup
  • 3 20-digit telephone numbers
  • Backup reporting; double reporting; split reporting
  • 195 User codes with opening/closing reportingby user
  • AC failure reporting with programmable reportdelay
  • Supervised telephone line cut with programmabledelay
  • Pager capability

SPECIFICATIONS

  • Operating temperature: 0-49ºC (32-120ºF)
  • Input power: 16.5Vac via Class 2 Plug-In 40VA Transformer, supplied
  • Loop voltage: 10-13VAC
  • Loop current: 2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke-detector zones
  • Loop resistance: 300W max.; 50W for 2-wire smoke detector zones
  • Relay outputs (burglary; reset; aux): wet, 12Vdc, 1.2A max.; dry (cut related jumper for dry contacts), SPDT contacts 24Vdc, 2A
  • Auxiliary power output: 12 Vdc regulated
  • Remote power output: 12Vdc regulated (for keypads) 750 mA combined Standby Current (Remote Power + Aux. Power + Reset Relay Power)
  • Standby time: Residential fire/burglary & commercial burglary, 4 hours minimum
  • EZM Module: GEM-EZM8: input, 50mA (including PGM Output) PGM output: 5mA, 12V special application
  • Keypad current: GEM-RP1CAe2, GEM K1CA: 100mA; 35mA if back lighting is disabled (cut W1, W2 & W3) PGM output: 5mA, 12V special application
  • Maximum number of keypads: 15 maximum wiring length for each run (#22AWG): 1000’ divided by total number of keypads & EZMs on run
  • Keypad Dimensions: 4 3/8” x 5 7/8” x 1 1/6” (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)

Downloads